NDTRADINGCANADA
AC power supply
PCR-MA Series
Compact AC Power Supply PCR-MA Series : 4 Models
The PCR-MA AC power supply series is a PWM inverter type (switching) power supply that builds on the success of our conventional model, the PCR-M. Maximum output voltage has been increased to 310Vrms AC while maintaining a compact, portable design. The digital interface now includes LAN (LXI) and USB as standard, with GPIB as a factory option for easy integration into any test system. The LXI compliant LAN interface allows the operator to easily monitor and control the instrument via virtual interface wherever they are. Various features including a remote sensing function have been introduced to ensure precise voltage and current measurements. Other features including DC mode, memory functions, and various protections make the PCR-MA the most accessible AC power supply on the market.
- Compact design
Small enough to fit on your work desk !
Only 214W X 124H X 350D mm !
Weights only 6 kg and easy to carry !
(PCR500MA)
- Selectable output modes
In addition to “AC mode” and “DC mode”, an AC+DC external analog interface board option (EX08-PCR-MA) allows for output control via “EXT-AC mode” and “EXT-DC mode” through external analog signals.
- Memory function
The PCR-MA can store up to three sets of output voltage, frequency, and limit value setting via front panel. Additionally, when using communication commands, the internal memory can store up to 11 settings.
- Versatile measurement capability
THE PCR-MA is capable of measuring the voltage, current and power of AC and DC output. It can also display the true RMS and average (DC) values of the output voltage as well as the true RMS, peak, and average (DC) values for the output current. When used with digital interface, the PCR-MA can also measure apparent power (VA), reactive power (VAR), power factor (PF), and peak hold current.
- Communication interface
LAN and USB digital interface included (GPIB optional)
- Easy access with the built-in web server
Use a browser from a PC, smartphone, or tablet to access the web server built into the PCR-MA series for convenient control and monitoring.
Model | Specification |
---|---|
PLZ205W | DC Electronic Load: Max. 200 W, 1–150 V, 40 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. *GPIB Option |
PLZ405W | DC Electronic Load: Max. 400 W, 1–150 V, 80 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. *GPIB Option |
PLZ1205W | DC Electronic Load: Max. 1200 W, 1–150 V, 240 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. *GPIB Option |
PLZ2405WB | Booster unit for PLZ1205W: Max. 2400 W, 1–150 V, 480 A. Able to connect up to four PLZ2405WB units in parallel to each PLZ1205W master unit (max. 10.8 kW, 2160 A). (Dedicated booster for PLZ1205W. Unable to connect to other models.) |
PLZ6005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 6000 W, 1–150 V, 1200 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ10005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 10.8 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ15005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 15.6 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ20005W SR | Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 20.4 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.” |
PLZ205WZ (SPEC21192) | DC load device with impedance measurement function in PLZ – 5W series. DC Electronic Load: Max. 200 W, 1–150 V, 40 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements. Measures AC frequency from 100 Hz – 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements. Measurement results and graphical information can be copied directly from the application software to programs like Excel. |
PLZ405WZ (SPEC21192) | DC load device with impedance measurement function in PLZ – 5W series. DC Electronic Load: Max. 400 W, 1–150 V, 80 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements. Measures AC frequency from 100 Hz – 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements.Measurement results and graphical information can be copied directly from the application software to programs like Excel. |
PLZ1205WZ (SPEC21192) | DC load device with impedance measurement function in PLZ – 5W series. DC Electronic Load: Max. 1200 W, 1–150 V, 240 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements.Measures AC frequency from 100 Hz – 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements. Measurement results and graphical information can be copied directly from the application software to programs like Excel. |